Warrior Tablet CA27 Environmental
Temperature IEC 68-2-1,2,14 / MIL-STD-810F, Method 501.4, 502.4 Operating: 0°C to 55°C/32°F to 131°F
Optional: -20°C to 55°C/-2°F to 131°F Non-operating : -40°C to 70°C/-38°F to 158°F
Humidity According to IEC 68-2-30 / MIL-STD-810F, Method 507.4
   5% to 95% RH, non-condensing
Altitude According to IEC 68-2-13 / MIL-STD-810F, Method 500.4
   Operating: 15,000ft, Non-operating: 40,000ft
   Altitude change rate: 2,000 ft/min
Shock According to IEC 68-2-27 / MIL-STD-810F, Method 516.5
   Operating: 15g/0.53 oz, 11 ms, half sine wave
   Non-operating: 50g/1.76 oz, 11 ms, half sine wave
Vibration According to IEC 68-2-6 / MIL-STD-810F, Method 514.5
   Operating: 10~55Hz/0.075g, 55~500Hz/1.0g
Non-operating: 10~55Hz/0.15g, 55~500Hz/2.0g
Highway truck vibration exposure
Drop According to IEC 68-2-32 / MIL-STD-810F, Method 516.5
   3 Feet height free drop still survive, (test surface: concrete, base unit only)
ESD Air Discharge: 0KV~8KV(included), no any error; 9KV~15KV, allow soft error
Contact Discharge:0KV~6KV(included), no any error; 7KV~ 8KV, allow soft error
Enclosure According to MIL-STD-810F/IEC 529, NEMA
Regulation FCC part 15, Subpart B, Class B, UL, CUL, TUV, CE, CCC, WHQL, BSMI,
MIL-STD-461E(option): CE102; CS114, 115 & 116; RE102; RS103
IP rating: A770-IP54; W130-IP51; CA25T/CA27-IP52
 Environmental subject to change without any notice. Rev. 12272005